KoohubKOOHUBفارسی
Aquaculture / overview

Installation & operation / 02

How does HMTR connect to your farm?

InstallationDry or wet
Water sourceFresh water, return water or both
Flow supplyGravity or a pump

1 — Dry installation: water passes directly through HMTR

Dry installation suits direct oxygenation of a defined stream passing entirely through the device. It can be assessed for many small and medium-sized farms and cold-water farms. The passing water reaches oxygen saturation at the HMTR outlet, without microbubble injection into a mixing basin.

In a dry installation, the HMTR body sits in a borehole up to 8 metres deep. Water enters and leaves through channels or pipes. The arrangement can serve a dedicated circuit, part of a farm or the whole farm.

Gravity-fed

Pump-fed

Gravity or a pump

Where sufficient flow and head (at least 2.5 metres) are available, water feeds the device by gravity. Otherwise, a pump supplies the required flow.

Fresh water, return water or both

Either feed arrangement can use the farm inlet, the return circuit or a combination of both. Each stream’s share is defined during design.

2 — Wet installation: oxygen supply and basin mixing

Wet installation can be assessed when mixing and oxygenation are needed for a flow larger than the flow passing through the device. Part of the water passes through HMTR, while fresh or return water enters the basin directly. The device discharge and bubble aeration work with circulation and dilution to increase dissolved oxygen in the mixed flow. This arrangement can suit large farms, including shrimp, sturgeon and recirculating systems, according to process design.

Fresh and return water can enter the basin directly, as defined by the design. The inlet baffle directs water downward; after circulation and mixing, it enters the farm’s distribution channel. Not all water needs to pass through HMTR.

Wet installation increases oxygen in the mixed flow; saturation of the whole mixed flow is not assumed. The treatable flow and final oxygen level depend on inlet conditions, oxygen transfer and basin design.

3 — Flow supply and unit configuration

A single HMTR sized for the required capacity can usually serve the farm; multiple units are not the default requirement. Several units are primarily considered for very large farms or separate processes and hydraulic circuits. Unit count and placement follow the farm’s capacity and hydraulic design.

4 — Compressed air: equipment and uses

Equipment can be custom-designed by Koohub or selected from commercial products compatible with the system’s pneumatic operating conditions.

Continue exploring